CEFR 4*50船用电缆执行标准:GB9331.2-88
用途及特性:
本产品适用于各种河海船舶及海上石油平台等水上建筑物传输电能用。电缆长期允许工作温度为85℃,额定电压Uo/U 为0.6/1KV。敷设时电缆Z小弯曲半径如下:金属屏蔽铠装型为电缆外径的6倍。非铠装型,外径小于等于25mm时为电缆外径的4倍,大于25mm为电缆外径的6倍。
CEFR 4*50船用电缆型号名称
CEFR/DA 乙丙绝缘氯丁护套船用电力软电缆,DA型,连接移动电器用。
技术要求:
1、应能经受单程30000次曲线试验。
2、电缆应能经受交流电压3500V或直流8400V,5min不击穿。
3、电缆线芯结构,绝缘电阻,绝缘和护套厚度及重量应符合GB9331.2-88的规定 。
CEFR-0.6/1KV-3*1.5 | CEFR-0.6/1KV-3*4+1*2.5 | CEFR-0.6/1KV-5*1.0 |
CEFR-0.6/1KV-3*2.5 | CEFR-0.6/1KV-3*6+1*4 | CEFR-0.6/1KV-7*1.0 |
CEFR-0.6/1KV-3*4 | CEFR-0.6/1KV-3*10+1*6 | CEFR-0.6/1KV-10*1.0 |
CEFR-0.6/1KV-3*6 | CEFR-0.6/1KV-3*16+1*10 | CEFR-0.6/1KV-12*1.0 |
CEFR-0.6/1KV-3*10 | CEFR-0.6/1KV-3*25+1*16 | CEFR-0.6/1KV-14*1.0 |
CEFR-0.6/1KV-3*16 | CEFR-0.6/1KV-3*35+1*16 | CEFR-0.6/1KV-19*1.0 |
CEFR-0.6/1KV-3*25 | CEFR-0.6/1KV-3*50+1*25 | CEFR-0.6/1KV-24*1.0 |
CEFR-0.6/1KV-3*35 | CEFR-0.6/1KV-3*70+1*35 | CEFR-0.6/1KV-27*1.0 |
CEFR-0.6/1KV-3*50 | CEFR-0.6/1KV-3*95+1*50 | CEFR-0.6/1KV-30*1.0 |
CEFR-0.6/1KV-3*70 | CEFR-0.6/1KV-3*120+1*70 | CEFR-0.6/1KV-33*1.0 |
CEFR-0.6/1KV-3*95 | CEFR-0.6/1KV-3*150+1*70 | CEFR-0.6/1KV-37*1.0 |
CEFR-0.6/1KV-3*120 | CEFR-0.6/1KV-3*185+1*95 | CEFR-0.6/1KV-5*1.5 |
CEFR-0.6/1KV-3*150 | CEFR-0.6/1KV-3*10+2*6 | CEFR-0.6/1KV-7*1.5 |
CEFR-0.6/1KV-3*185 | CEFR-0.6/1KV-3*16+2*10 | CEFR-0.6/1KV-10*1.5 |
CEFR-0.6/1KV-4*1.5 | CEFR-0.6/1KV-3*25+2*16 | CEFR-0.6/1KV-12*1.5 |
CEFR-0.6/1KV-4*2.5 | CEFR-0.6/1KV-3*35+2*16 | CEFR-0.6/1KV-14*1.5 |
CEFR-0.6/1KV-4*4 | CEFR-0.6/1KV-3*50+2*25 | CEFR-0.6/1KV-19*1.5 |
CEFR-0.6/1KV-4*6 | CEFR-0.6/1KV-3*70+2*35 | CEFR-0.6/1KV-24*1.5 |
CEFR-0.6/1KV-4*10 | CEFR-0.6/1KV-3*95+2*50 | CEFR-0.6/1KV-27*1.5 |
CEFR-0.6/1KV-4*16 | CEFR-0.6/1KV-3*120+2*70 | CEFR-0.6/1KV-30*1.5 |
CEFR-0.6/1KV-4*25 | CEFR-0.6/1KV-3*150+2*70 | CEFR-0.6/1KV-33*1.5 |
CEFR-0.6/1KV-4*35 | CEFR-0.6/1KV-3*185+2*95 | CEFR-0.6/1KV-37*1.5 |
CEFR-0.6/1KV-4*50 | CEFR-0.6/1KV-3*240+2*120 | CEFR-0.6/1KV-5*2.5 |
CEFR-0.6/1KV-4*70 | CEFR-0.6/1KV-4*10+1*6 | CEFR-0.6/1KV-7*2.5 |
CEFR-0.6/1KV-4*95 | CEFR-0.6/1KV-4*16+1*10 | CEFR-0.6/1KV-10*2.5 |
CEFR-0.6/1KV-4*120 | CEFR-0.6/1KV-4*25+1*16 | CEFR-0.6/1KV-12*2.5 |
CEFR-0.6/1KV-1*120 | CEFR-0.6/1KV-4*35+1*16 | CEFR-0.6/1KV-14*2.5 |
CEFR-0.6/1KV-1*150 | CEFR-0.6/1KV-4*50+1*25 | CEFR-0.6/1KV-19*2.5 |
CEFR-0.6/1KV-1*185 | CEFR-0.6/1KV-4*70+1*35 | CEFR-0.6/1KV-24*2.5 |
CEFR-0.6/1KV-1*240 | CEFR-0.6/1KV-4*95+1*50 | CEFR-0.6/1KV-27*2.5 |
CEFR-0.6/1KV-1*300 | CEFR-0.6/1KV-4*120+1*70 | CEFR-0.6/1KV-30*2.5 |
CEFR-0.6/1KV-1*400 | CEFR-0.6/1KV-1*95 | CEFR-0.6/1KV-32*2.5 |
CEFR-0.6/1KV-1*500 | CEFR-0.6/1KV-1*70 | CEFR-0.6/1KV-37*2.5 |
注意事项:
1、绝缘老化变质
电力电缆绝缘要受到伴随电作用带来的热、化学及机械作用,从而使绝缘介质发生物理及化学变化,使介质的绝缘水平下降。绝缘受潮。中间接头或终端头因结构上下密封或安装质量不好而造成绝缘受潮;制造电缆包铅时留下砂眼或裂纹等缺陷,也会使电缆受潮。
2、电缆过热
造成电缆过热的原因有很多。内因是电缆绝缘内部气隙游离造成局部受热,从而使绝缘炭化。外因是安装在电缆密集地区、电缆隧道等处的电缆,穿在干燥管中的电缆以及与管道接近的电缆,会因电缆过负荷或散热不良,而使绝缘加速损坏。
3、机械损伤
主要是指外力作用造成的电缆损伤。这主要是由于车辆振动等机械作用,使电缆变形。电缆变形导致弯曲过度,损坏了内绝缘或导致绝缘内部产生气隙。
4、护层腐蚀
由于电解作用或化学作用使电缆铅包腐蚀,因腐蚀性质和程度的不同,铅包上有红色、黄色、橙色和淡黄色的化合物或类似海绵的细孔。
5、过电压造成击穿
大气过电压和内部过电压使电缆绝缘所承受的应力超过允许值而造成击穿。而且,对实际故障进行分析表明,许多户外终端头故障,是由于大气过电压引起的。